1. two-stage filters provide high performance in suppressing both line-to-line and line-to-ground noise.2. all part numbers are ul recognized, csa certified and vde approved. e n g l n i l c1 l' g' n' c2 cy cy l1 r d l2 c3 a o l 1. maximum leakage current each line-to-ground @ 115v ac 60hz: 0.25ma @ 250vac 50hz: 0.45ma2. hipot rating (one minute) line-to-ground: 2250vdc line-to-line: 1450vdc 3. operating frequency: 50/60hz 4. rated voltage: 115/250v ac part no. 02drcg502drcw5 03DRCG5 03drcw5 03drdg3s 03drdw3s 05drcg5 05drcw5 05drdg3 05drdg3s 05drdw3s 10drcg5 10drcs5 10drcw5 10drdg3 15drcg5 20drgg5 20drgs5 c1,c2,c3(uf) l1,l2(mh) 0.22 0.1 1.0 0.9 0.1 0.22 1.0 1.3 1.3 2.7 1.6 2.8 1.7 2.4 dimensions in inches/mm a b c d e 2.94 74.4 1.575 40.01 1.82 46.2 2.38 60.5 3.33 84.6 3.75 95.3 2.22 56.4 4.14 105.1 1.27 32.3 1.52 1.27 1.52 5.14 38.6 32.3 38.6 130.5 2.02 51.3 1.575 40.00 2.04 51.82.20 55.9 2.94 74.7 3.34 84.5 0.63 16.0 0.61 15.5 0.63 16.0 3.34 84.8 1.15 29.2 1.28 32.5 1.15 29.2 2.02 51.3 1.575 40.00 2.02 51.32.04 51.8 2.94 74.7 0.61 15.5 3.34 84.8 2.77 70.42.77 70.4 3.25 82.5 2.08 52.8 3.75 95.2 2.58 65.5 3.14 79.8 2.55 64.8 3.75 95.2 2.58 65.5 4.33 110.0 3.14 79.8 2.55 64.8 3.75 95.2 3.87 98.3 2.50 63.5 4.35 110.5 3.75 95.2 2.08 52.8 1.79 45.5 2.94 74.7 3.36 85.3 part no. 02drcg502drcw5 03DRCG5 03drcw5 03drdg3s 03drdw3s 05drcg5 05drcw5 05drdg3 05drdg3s 05drdw3s 10drcg5 10drcs5 10drcw5 10drdg3 15drcg5 20drgg5 20drgs5 d v e 6-7 r: 2.2m , cy: 3300pf. no safety approval yet, r: 1.0m vde approved to 16a/250vac, c2: 0.33 uf * * g e n e r a l p u r p o s e t w o - s t a g e f i l t e r s series high performance fil ters introductions specifications components series dimensions electrical schematic
gg5 a m a x . c m a x . e m a x . b m a x . d 5 0 .8 2 .0 0 .2 5 5 x 0 .1 5 7 6 .5 x 4 .0 cw5 b m a x . a m ax. e ma x. d 0.188 4.8 c m a x . all w ire lea ds 4.0" l ong min . current frequency-mhz rating .15 .50 1.0 5.0 10 30 2 40 60 65 55 50 40 3, 5a 40 60 65 65 60 45 3, 5a(s) 38 60 65 55 45 40 10a 30 60 65 50 45 40 15a 23 45 50 45 40 30 20a 20 35 40 50 55 40 2 5 50 65 60 54 46 3, 5a 12 60 65 60 54 46 3, 5a(s) 10 65 70 70 60 50 10a 7 53 60 55 45 40 15a 8 30 40 45 40 40 20a 7 55 50 50 55 40 common mode (l-g) in 50 ohm system differential mode (l-l) in 50 ohm system 02 dr cg 5 05 dr cg 5 10 k 40 db 80 db 60 db 20 db 0 d b 40 db 80 db 60 db 20 db 0 d b 10 0k 1m 10 m co mm on mo de co mm on mo de dif f. mo de dif f. mo de co mm on mo de co mm on mo de dif f. mo de dif f. mo de 10 dr cg 5 10 k 10 0k 10 dr dg 3 1m 10 m unit: inch mm 6-8 g e n e r a l p u r p o s e t w o - s t a g e f i l t e r s b lu e b lu e b r o w n b r o w n g /y mechanical construction minimum insertion loss in db insertion loss (typical)
dg3/dg3s dw3s all wire leads 4 .0" long min. suggested mounting c utout #8-32 cg5 gs5 cs5 c m a x . b m a x . e a max. d 0.188 4.8 c m a x . b m a x . a max. d e #8-32 0.188 4.8 unit: inch mm 6-9 a m a x . c m a x . e m a x . b m a x . d 5 0 .8 2 .0 0 .2 5 5 x 0 .1 5 7 6 .5 x 4 .0 e a b c d 5 2 1 suggested mounting c utout #6-32x 1/4 tapp ed ins ert e a b c 1.575 0.005 - 0 . 9 1 0 0.157 4.0 40.0 0.13 r0.24max. 31.0 0.13 1.22 0.005 r6.0max. + - + 0 . 0 0 5 2 3 . 1 - 0 + 0 . 1 3 d 5 2 1 + - + - + - #6-32x 1/4 tapp ed ins ert 1.575 0.005 - 0 . 9 1 0 0.157 4.0 40.0 0.13 r0.24max. 31.0 0.13 1.22 0.005 r6.0max. + - + 0 . 0 0 5 2 3 . 1 - 0 + 0 . 1 3 + - + - + - g e n e r a l p u r p o s e t w o - s t a g e f i l t e r s b l u e b r o w n g /y mechanical construction
|